<?xml version="1.0" encoding="UTF-8"?>
<netcdf xmlns="http://www.unidata.ucar.edu/namespaces/netcdf/ncml-2.2" location="Not provided because of security concerns.">
  <attribute name="Conventions" value="CF-1.8, ACDD-1.3" />
  <attribute name="featureType" value="timeSeries" />
  <attribute name="title" value="VOC (hydrocarbons) at Beromünster" />
  <attribute name="summary" value="VOC (hydrocarbons) at Beromünster. These measurements are gathered as a part of the following projects ACTRIS_NRT and they are stored in the EBAS database (http://ebas.nilu.no/). Parameters measured are: ['2-methylbutane in air (mass_concentration_of_2-methylbutane_in_air)', '2-methylbutane in air (mole_fraction_of_2_methylbutane_in_air)', '2-methylpropane in air (mass_concentration_of_2-methylpropane_in_air)', '2-methylpropane in air (mole_fraction_of_2_methylpropane_in_air)', 'benzene in air (mole_fraction_of_benzene_in_air)', 'ethane in air (mass_concentration_of_ethane_in_air)', 'ethane in air (mole_fraction_of_ethane_in_air)', 'n-butane in air (mass_concentration_of_n-butane_in_air)', 'n-butane in air (mole_fraction_of_butane_in_air)', 'n-pentane in air (mass_concentration_of_n-pentane_in_air)', 'n-pentane in air (mole_fraction_of_pentane_in_air)', 'propane in air (mass_concentration_of_propane_in_air)', 'propane in air (mole_fraction_of_propane_in_air)', 'toluene in air (mole_fraction_of_toluene_in_air)']" />
  <attribute name="keywords" value="Beromünster CH0053R 2-methylbutane 2-methylpropane benzene ethane n-butane n-pentane propane toluene air ACTRIS_NRT mass_concentration_of_2-methylbutane_in_air mole_fraction_of_2_methylbutane_in_air mass_concentration_of_2-methylpropane_in_air mole_fraction_of_2_methylpropane_in_air mole_fraction_of_benzene_in_air mass_concentration_of_ethane_in_air mole_fraction_of_ethane_in_air mass_concentration_of_n-butane_in_air mole_fraction_of_butane_in_air mass_concentration_of_n-pentane_in_air mole_fraction_of_pentane_in_air mass_concentration_of_propane_in_air mole_fraction_of_propane_in_air mole_fraction_of_toluene_in_air" />
  <attribute name="id" value="UYP3-JCXS.nc" />
  <attribute name="naming_authority" value="EBAS" />
  <attribute name="project" value="ACTRIS_NRT" />
  <attribute name="acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: ACTRIS_NRT." />
  <attribute name="doi" value="https://doi.org/10.48597/UYP3-JCXS" />
  <attribute name="license" value="https://creativecommons.org/licenses/by/4.0/" />
  <attribute name="citation" value="Constantin, L., Rubli, P., Reimann, S., ACTRIS_NRT, 2026, VOC (hydrocarbons) at Beromünster, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/UYP3-JCXS accessed at 2026-11-25T08:00:01.649686Z" />
  <attribute name="source" value="surface observation" />
  <attribute name="institution" value="CH01L &quot;Swiss Federal Laboratories for Materials Science and Technology&quot; EMPA &quot;Section Air Pollution&quot; &quot;Überlandstrasse 133&quot; 8600 Dübendorf Switzerland" />
  <attribute name="processing_level" value="processing_level_test" />
  <attribute name="date_created" value="2026-11-25T08:00:01.649686Z" />
  <attribute name="date_metadata_modified" value="2026-11-25T07:37:17Z" />
  <attribute name="creator_name" value="Lionel Constantin, Pascal Rubli, Stefan Reimann" />
  <attribute name="creator_type" value="person" />
  <attribute name="creator_email" value="lionel.constantin@empa.ch, pascal.rubli@empa.ch, " />
  <attribute name="creator_institution" value="&quot;Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Air Pollution, EMPA&quot;, &quot;Swiss Federal Laboratories for Materials Science and Technology, Air Pollution/Environmental Technology, Empa&quot;, " />
  <attribute name="contributor_name" value="Lionel Constantin" />
  <attribute name="contributor_role" value="data submitter" />
  <attribute name="publisher_type" value="institution" />
  <attribute name="publisher_name" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_institution" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_email" value="ebas@nilu.no" />
  <attribute name="publisher_url" value="https://www.nilu.no/" />
  <attribute name="geospatial_bounds" value="POINT Z (8.175433684 47.18961391 797)" />
  <attribute name="geospatial_lat_min" type="double" value="47.18961391" />
  <attribute name="geospatial_lat_max" type="double" value="47.18961391" />
  <attribute name="geospatial_lon_min" type="double" value="8.175433684" />
  <attribute name="geospatial_lon_max" type="double" value="8.175433684" />
  <attribute name="geospatial_vertical_min" type="double" value="797.0" />
  <attribute name="geospatial_vertical_max" type="double" value="797.0" />
  <attribute name="geospatial_vertical_positive" value="up" />
  <attribute name="geospatial_bounds_crs" value="EPSG:4979" />
  <attribute name="time_coverage_start" value="2026-07-01T13:50:00Z" />
  <attribute name="time_coverage_end" value="2026-11-25T06:17:00Z" />
  <attribute name="time_coverage_duration" value="P0000-04-23T16:27:00" />
  <attribute name="time_coverage_resolution" value="P0000-00-00T01:00:00" />
  <attribute name="timezone" value="UTC" />
  <attribute name="ebsint_fileformatversion" value="4.07.08" />
  <attribute name="ebas_data_definition" value="EBAS_1.1" />
  <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
  <attribute name="ebas_citation" value="Constantin, L., Rubli, P., Reimann, S., ACTRIS_NRT, 2026, VOC (hydrocarbons) at Beromünster, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/UYP3-JCXS accessed at 2026-11-25T08:00:01.649686Z" />
  <attribute name="ebas_set_type_code" value="TI" />
  <attribute name="ebas_timezone" value="UTC" />
  <attribute name="ebas_file_name" value="UYP3-JCXS.nc" />
  <attribute name="ebas_represents_doi" value="https://doi.org/10.48597/UYP3-JCXS" />
  <attribute name="ebas_contains_doi" value="https://doi.org/10.48597/UYP3-JCXS" />
  <attribute name="ebas_file_creation" value="2026-11-25T08:00:04.679941Z" />
  <attribute name="ebas_export_state" value="2026-11-25T08:00:01.649686Z" />
  <attribute name="ebas_export_filter" value="exclude-900,exclude-invalid" />
  <attribute name="ebas_startdate" value="2026-07-01T13:50:00.000000Z" />
  <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
  <attribute name="ebas_input_dataset" value="" />
  <attribute name="ebas_software" value="" />
  <attribute name="ebas_statistics" value="arithmetic mean" />
  <attribute name="ebas_data_level" value="1.5" />
  <attribute name="ebas_period_code" value="21w" />
  <attribute name="ebas_resolution_code" value="1h" />
  <attribute name="ebas_station_code" value="CH0053R" />
  <attribute name="ebas_platform_code" value="CH0053S" />
  <attribute name="ebas_station_name" value="Beromünster" />
  <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
  <attribute name="ebas_station_gaw_id" value="BRM" />
  <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
  <attribute name="ebas_station_land_use" value="Agricultural" />
  <attribute name="ebas_station_setting" value="Rural" />
  <attribute name="ebas_station_gaw_type" value="R" />
  <attribute name="ebas_station_wmo_region" type="long" value="7" />
  <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
  <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
  <attribute name="ebas_station_altitude" value="797.0 m" />
  <attribute name="ebas_regime" value="IMG" />
  <attribute name="ebas_matrix" value="air" />
  <attribute name="ebas_laboratory_code" value="CH01L" />
  <attribute name="ebas_instrument_type" value="online_gc" />
  <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
  <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
  <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
  <attribute name="ebas_instrument_serial_number" value="cn17373012" />
  <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
  <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
  <attribute name="ebas_inlet_type" value="Hat or hood" />
  <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
  <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
  <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
  <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
  <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
  <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
  <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
  <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
  <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: ACTRIS_NRT." />
  <attribute name="_NCProperties" value="version=2,netcdf=4.10.1,hdf5=2.2.0" />
  <attribute name="Metadata_Conventions" value="Unidata Dataset Discovery v1.0" />
  <attribute name="geospatial_lat_units" value="degrees_north" />
  <attribute name="geospatial_lon_units" value="degrees_east" />
  <attribute name="standard_name_vocabulary" value="CF-1.7, ACDD-1.3" />
  <attribute name="history" value="None" />
  <attribute name="creator_url" value="ebas.nilu.no" />
  <attribute name="_CoordSysBuilder" value="ucar.nc2.internal.dataset.conv.CF1Convention" />
  <dimension name="time" length="2831" />
  <dimension name="tbnds" length="2" />
  <dimension name="metadata_time" length="1" />
  <dimension name="qc_2_methylbutane_ng_per_m3_flags" length="3" />
  <dimension name="qc_2_methylbutane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_2_methylpropane_ng_per_m3_flags" length="3" />
  <dimension name="qc_2_methylpropane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_benzene_ng_per_m3_flags" length="3" />
  <dimension name="qc_benzene_pmol_per_mol_flags" length="3" />
  <dimension name="qc_ethane_ng_per_m3_flags" length="3" />
  <dimension name="qc_ethane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_n_butane_ng_per_m3_flags" length="3" />
  <dimension name="qc_n_butane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_n_pentane_ng_per_m3_flags" length="3" />
  <dimension name="qc_n_pentane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_propane_ng_per_m3_flags" length="3" />
  <dimension name="qc_propane_pmol_per_mol_flags" length="3" />
  <dimension name="qc_toluene_ng_per_m3_flags" length="3" />
  <dimension name="qc_toluene_pmol_per_mol_flags" length="3" />
  <group name="CFMetadata">
    <attribute name="time_coverage_start" value="2026-07-01T14:00:00Z" />
    <attribute name="time_coverage_end" value="2026-11-25T06:07:00Z" />
    <attribute name="time_coverage_units" value="seconds" />
    <attribute name="time_coverage_resolution" value="4477.0" />
    <attribute name="time_coverage_duration" value="P0Y0M146DT16H7M0.000S" />
  </group>
  <group name="NCISOMetadata">
    <attribute name="metadata_creation" value="2026-11-25" />
    <attribute name="nciso_version" value="2.4.9" />
  </group>
  <variable name="time_bnds" shape="time tbnds" type="double">
    <attribute name="long_name" value="time bounds for measurement" />
  </variable>
  <variable name="metadata_time_bnds" shape="metadata_time tbnds" type="double">
    <attribute name="long_name" value="time bounds for ebas metadata intervals" />
  </variable>
  <variable name="v_2_methylbutane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_2-methylbutane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_2_methylbutane_ng_per_m3 meta_2_methylbutane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="2-methylbutane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 3.2190194758458066." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/2-methylbutanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="2-methylbutane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_2_methylbutane_ng_per_m3" shape="qc_2_methylbutane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_2_methylbutane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_2_methylbutane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_2_methylbutane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_2_methylbutane_pmol_per_mol meta_2_methylbutane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="2-methylbutane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/2-methylbutaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="2-methylbutane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_2_methylbutane_pmol_per_mol" shape="qc_2_methylbutane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_2_methylbutane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_2_methylpropane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_2-methylpropane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_2_methylpropane_ng_per_m3 meta_2_methylpropane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="2-methylpropane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 2.5932043632667829." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/2-methyl-propanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="2-methyl-propane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_2_methylpropane_ng_per_m3" shape="qc_2_methylpropane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_2_methylpropane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_2_methylpropane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_2_methylpropane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_2_methylpropane_pmol_per_mol meta_2_methylpropane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="2-methylpropane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/2-methyl-propaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="2-methyl-propane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_2_methylpropane_pmol_per_mol" shape="qc_2_methylpropane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_2_methylpropane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_benzene_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_benzene_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_benzene_ng_per_m3 meta_benzene_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="benzene" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 3.48505893662207544." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/benzenemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="benzene mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_benzene_ng_per_m3" shape="qc_benzene_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_benzene_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_benzene_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_benzene_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_benzene_pmol_per_mol meta_benzene_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="benzene" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/benzeneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="benzene amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_benzene_pmol_per_mol" shape="qc_benzene_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_benzene_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_ethane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_ethane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_ethane_ng_per_m3 meta_ethane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="ethane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 1.341574138108736." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/ethanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="ethane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_ethane_ng_per_m3" shape="qc_ethane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_ethane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_ethane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_ethane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_ethane_pmol_per_mol meta_ethane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="ethane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/ethaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="ethane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_ethane_pmol_per_mol" shape="qc_ethane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_ethane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_n_butane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_n-butane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_n_butane_ng_per_m3 meta_n_butane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="n-butane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 2.5932043632667829." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/n-butanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="n-butane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_n_butane_ng_per_m3" shape="qc_n_butane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_n_butane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_n_butane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_butane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_n_butane_pmol_per_mol meta_n_butane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="n-butane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/n-butaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="n-butane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_n_butane_pmol_per_mol" shape="qc_n_butane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_n_butane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_n_pentane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_n-pentane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_n_pentane_ng_per_m3 meta_n_pentane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="n-pentane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 3.2190194758458066." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/n-pentanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="n-pentane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_n_pentane_ng_per_m3" shape="qc_n_pentane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_n_pentane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_n_pentane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_pentane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_n_pentane_pmol_per_mol meta_n_pentane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="n-pentane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/n-pentaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="n-pentane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_n_pentane_pmol_per_mol" shape="qc_n_pentane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_n_pentane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_propane_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_propane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_propane_ng_per_m3 meta_propane_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="propane" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 1.967389250687759." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/propanemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="propane mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_propane_ng_per_m3" shape="qc_propane_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_propane_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_propane_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_propane_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_propane_pmol_per_mol meta_propane_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="propane" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/propaneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="propane amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_propane_pmol_per_mol" shape="qc_propane_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_propane_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_toluene_ng_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_toluene_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ng/m3" />
    <attribute name="ancillary_variables" value="qc_toluene_ng_per_m3 meta_toluene_ng_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="toluene" />
    <attribute name="ebas_unit" value="ng/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="ebas_comment" value="Data converted on export from EBAS from 'pmol/mol' to 'ng/m3' at 273.15 K, 1013.25 hPa, conversion factor 4.1108740492010982." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/toluenemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="toluene mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_toluene_ng_per_m3" shape="qc_toluene_ng_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_toluene_ng_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_toluene_pmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_toluene_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="pmol/mol" />
    <attribute name="ancillary_variables" value="qc_toluene_pmol_per_mol meta_toluene_pmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebsint_dimnames" value="time" />
    <attribute name="ebas_data_license" value="https://creativecommons.org/licenses/by/4.0/" />
    <attribute name="ebas_revision_date" value="2026-11-25T07:37:17.000000Z" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="1.5" />
    <attribute name="ebas_station_code" value="CH0053R" />
    <attribute name="ebas_platform_code" value="CH0053S" />
    <attribute name="ebas_station_name" value="Beromünster" />
    <attribute name="ebas_station_wdca_id" value="GAWACH__BRM" />
    <attribute name="ebas_station_gaw_id" value="BRM" />
    <attribute name="ebas_station_gaw_name" value="BEROMUENSTER" />
    <attribute name="ebas_station_land_use" value="Agricultural" />
    <attribute name="ebas_station_setting" value="Rural" />
    <attribute name="ebas_station_gaw_type" value="R" />
    <attribute name="ebas_station_wmo_region" type="long" value="7" />
    <attribute name="ebas_station_latitude" type="double" value="47.18961391" />
    <attribute name="ebas_station_longitude" type="double" value="8.175433684" />
    <attribute name="ebas_station_altitude" value="797.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="toluene" />
    <attribute name="ebas_unit" value="pmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="CH01L" />
    <attribute name="ebas_instrument_type" value="online_gc" />
    <attribute name="ebas_instrument_name" value="Agilent_MARKES-GC-FID_cn17373012_BRM_NRT" />
    <attribute name="ebas_instrument_manufacturer" value="MARKES+MARKES+Agilent" />
    <attribute name="ebas_instrument_model" value="Air Server+UNITY2+7890A GC/FID" />
    <attribute name="ebas_instrument_serial_number" value="cn17373012" />
    <attribute name="ebas_method_ref" value="CH01L_MARKES_GC_FID_VOCAIR_BRM" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Batch: NPL standard " />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_organization" value="CH01L, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Section Air Pollution, Überlandstrasse 133, , 8600, Dübendorf, Switzerland" />
    <attribute name="ebas_framework_acronym" value="ACTRIS_NRT" />
    <attribute name="ebas_framework_name" value="&quot;Near Realtime Data for European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases&quot;" />
    <attribute name="ebas_framework_description" value="&quot;ACTRIS is the European Research Infrastructure for the observation of Aerosol, Clouds, and Trace gases. ACTRIS is composed of observing stations, exploratory platforms, instruments calibration centres, and a data centre.&quot;" />
    <attribute name="ebas_framework_contact_name" value="Cathrine Lund Myhre" />
    <attribute name="ebas_framework_contact_email" value="clm@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;, &quot;Rubli, Pascal, pascal.rubli@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland&quot;, &quot;Reimann, Stefan, , , , , , , , , &quot;" />
    <attribute name="ebas_submitter" value="&quot;Constantin, Lionel, lionel.constantin@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, EMPA, Laboratory for Air Pollution, Ueberlandstrasse 129, , 8600, Duebendorf, Switzerland&quot;" />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/tolueneamountfraction" />
    <attribute name="actris_variable_preferred_term" value="toluene amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/realreal-time" />
    <attribute name="actris_timeliness_preferred_term" value="real real-time" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gaschromatograph-online" />
    <attribute name="actris_instrument_type_preferred_term" value="gas chromatograph, online" />
    <attribute name="actris_framework_uri" value="https://vocabulary.actris.nilu.no/actris_controlled_lists/ACTRIS" />
    <attribute name="actris_framework_preferred_term" value="ACTRIS" />
    <attribute name="actris_temporal_resolution" value="PT1H" />
    <attribute name="actris_access_restriction" type="long" value="0" />
  </variable>
  <variable name="qc_toluene_pmol_per_mol" shape="qc_toluene_pmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_toluene_pmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="time" shape="time" type="double">
    <attribute name="long_name" value="time of measurement" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01T00:00:00Z" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="standard" />
    <attribute name="bounds" value="time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>
  <variable name="metadata_time" shape="metadata_time" type="double">
    <attribute name="long_name" value="time of ebas metadata intervals" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01T00:00:00Z" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="standard" />
    <attribute name="bounds" value="metadata_time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>
</netcdf>