<?xml version="1.0" encoding="UTF-8"?>
<netcdf xmlns="http://www.unidata.ucar.edu/namespaces/netcdf/ncml-2.2" location="Not provided because of security concerns.">
  <attribute name="Conventions" value="CF-1.8, ACDD-1.3" />
  <attribute name="featureType" value="timeSeries" />
  <attribute name="title" value="Nitrogen oxides at ISAC Bologna II" />
  <attribute name="summary" value="Nitrogen oxides at ISAC Bologna II. These measurements are gathered as a part of the following projects CAMPAIGN and they are stored in the EBAS database (http://ebas.nilu.no/). Parameters measured are: ['pressure in instrument', 'temperature in instrument', 'nitrogen_dioxide in air (mole_fraction_of_nitrogen_dioxide_in_air)', 'nitrogen_dioxide in air (mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air)', 'nitrogen_monoxide in air (mole_fraction_of_nitrogen_monoxide_in_air)', 'nitrogen_monoxide in air (mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air)']" />
  <attribute name="keywords" value="&quot;ISAC Bologna II&quot; IT0022C nitrogen_dioxide nitrogen_monoxide air CAMPAIGN mole_fraction_of_nitrogen_dioxide_in_air mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air mole_fraction_of_nitrogen_monoxide_in_air mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
  <attribute name="id" value="JZP7-NYPN.nc" />
  <attribute name="naming_authority" value="EBAS" />
  <attribute name="project" value="CAMPAIGN" />
  <attribute name="acknowledgement" value="" />
  <attribute name="doi" value="https://doi.org/10.48597/JZP7-NYPN" />
  <attribute name="license" value="https://creativecommons.org/licenses/by/4.0/" />
  <attribute name="citation" value="Putero, D., Cristofanelli, P., Busetto, M., CAMPAIGN, 2024, Nitrogen oxides at ISAC Bologna II, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/JZP7-NYPN" />
  <attribute name="source" value="surface observation" />
  <attribute name="institution" value="IT06L &quot;Institute of Atmospheric Sciences and Climate&quot; CNR-ISAC &quot;Section of Bologna&quot; &quot;Via Gobetti 101&quot; 40129 Bologna Italy" />
  <attribute name="processing_level" value="processing_level_test" />
  <attribute name="date_created" value="2026-01-05T10:23:58.085248Z" />
  <attribute name="date_metadata_modified" value="2024-12-03T14:13:00Z" />
  <attribute name="creator_name" value="Davide Putero, Paolo Cristofanelli, Maurizio Busetto" />
  <attribute name="creator_type" value="person" />
  <attribute name="creator_email" value="d.putero@isac.cnr.it, p.cristofanelli@isac.cnr.it, m.busetto@isac.cnr.it" />
  <attribute name="creator_institution" value="&quot;Institute of Atmospheric Sciences and Climate, ISAC&quot;, &quot;National Research Council of Italy, Institute for Atmospheric and Climate Science, CNR&quot;, &quot;National Research Council of Italy, Institute for Atmospheric and Climate Science, CNR&quot;" />
  <attribute name="contributor_name" value="Davide Putero" />
  <attribute name="contributor_role" value="data submitter" />
  <attribute name="publisher_type" value="institution" />
  <attribute name="publisher_name" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_institution" value="NILU - Norwegian Institute for Air Research, ATMOS, EBAS" />
  <attribute name="publisher_email" value="ebas@nilu.no" />
  <attribute name="publisher_url" value="https://www.nilu.no/" />
  <attribute name="geospatial_bounds" value="POINT Z (11.338474 44.523586 54)" />
  <attribute name="geospatial_lat_min" type="double" value="44.523586" />
  <attribute name="geospatial_lat_max" type="double" value="44.523586" />
  <attribute name="geospatial_lon_min" type="double" value="11.338474" />
  <attribute name="geospatial_lon_max" type="double" value="11.338474" />
  <attribute name="geospatial_vertical_min" type="double" value="54.0" />
  <attribute name="geospatial_vertical_max" type="double" value="54.0" />
  <attribute name="geospatial_vertical_positive" value="up" />
  <attribute name="geospatial_bounds_crs" value="EPSG:4979" />
  <attribute name="time_coverage_start" value="2024-09-01T00:00:00Z" />
  <attribute name="time_coverage_end" value="2024-10-01T00:00:00Z" />
  <attribute name="time_coverage_duration" value="P0000-01-00T00:00:00" />
  <attribute name="time_coverage_resolution" value="P0000-00-00T00:00:00" />
  <attribute name="timezone" value="UTC" />
  <attribute name="ebas_data_definition" value="EBAS_1.1" />
  <attribute name="ebas_data_license" value="" />
  <attribute name="ebas_citation" value="Putero, D., Cristofanelli, P., Busetto, M., CAMPAIGN, 2024, Nitrogen oxides at ISAC Bologna II, data hosted by EBAS at NILU, DOI: https://doi.org/10.48597/JZP7-NYPN" />
  <attribute name="ebas_set_type_code" value="TI" />
  <attribute name="ebas_timezone" value="UTC" />
  <attribute name="ebas_file_name" value="JZP7-NYPN.nc" />
  <attribute name="ebas_represents_doi" value="https://doi.org/10.48597/JZP7-NYPN" />
  <attribute name="ebas_contains_doi" value="https://doi.org/10.48597/JZP7-NYPN" />
  <attribute name="ebas_file_creation" value="2026-06-13T02:18:00.514657Z" />
  <attribute name="ebas_export_state" value="2026-01-05T10:23:58.085248Z" />
  <attribute name="ebas_export_filter" value="exclude-900,exclude-invalid" />
  <attribute name="ebas_startdate" value="2024-09-01T00:00:00.000000Z" />
  <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
  <attribute name="ebas_version" value="1" />
  <attribute name="ebas_version_description" value="first revision, manually inspected" />
  <attribute name="ebas_statistics" value="arithmetic mean" />
  <attribute name="ebas_data_level" value="0" />
  <attribute name="ebas_period_code" value="1mo" />
  <attribute name="ebas_resolution_code" value="1mn" />
  <attribute name="ebas_sample_duration" value="1mn" />
  <attribute name="ebas_orig_time_res" value="1mn" />
  <attribute name="ebas_station_code" value="IT0022C" />
  <attribute name="ebas_platform_code" value="IT0022S" />
  <attribute name="ebas_station_name" value="ISAC Bologna II" />
  <attribute name="ebas_station_land_use" value="Residential" />
  <attribute name="ebas_station_setting" value="Suburban" />
  <attribute name="ebas_station_latitude" type="double" value="44.523586" />
  <attribute name="ebas_station_longitude" type="double" value="11.338474" />
  <attribute name="ebas_station_altitude" value="54.0 m" />
  <attribute name="ebas_measurement_height" value="7.0 m" />
  <attribute name="ebas_regime" value="IMG" />
  <attribute name="ebas_laboratory_code" value="IT06L" />
  <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
  <attribute name="ebas_instrument_name" value="T200UP_168" />
  <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
  <attribute name="ebas_instrument_model" value="T200UP" />
  <attribute name="ebas_instrument_serial_number" value="168" />
  <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
  <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
  <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
  <attribute name="ebas_inlet_type" value="Hat or hood" />
  <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
  <attribute name="ebas_inlet_tube_material" value="Teflon" />
  <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
  <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
  <attribute name="ebas_humidity_temperaure_control" value="None" />
  <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
  <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
  <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
  <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
  <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
  <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
  <attribute name="ebas_framework_name" value="" />
  <attribute name="ebas_framework_description" value="" />
  <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
  <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
  <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
  <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
  <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
  <attribute name="_NCProperties" value="version=2,netcdf=4.9.3,hdf5=1.14.6" />
  <attribute name="Metadata_Conventions" value="Unidata Dataset Discovery v1.0" />
  <attribute name="geospatial_lat_units" value="degrees_north" />
  <attribute name="geospatial_lon_units" value="degrees_east" />
  <attribute name="standard_name_vocabulary" value="CF-1.7, ACDD-1.3" />
  <attribute name="history" value="None" />
  <attribute name="creator_url" value="ebas.nilu.no" />
  <attribute name="_CoordSysBuilder" value="ucar.nc2.internal.dataset.conv.CF1Convention" />
  <dimension name="time" length="42557" />
  <dimension name="tbnds" length="2" />
  <dimension name="metadata_time" length="1" />
  <dimension name="d_Location" length="1" />
  <dimension name="qc_pressure_flags" length="1" />
  <dimension name="qc_temperature_flags" length="1" />
  <dimension name="qc_nitrogen_dioxide_nmol_per_mol_flags" length="1" />
  <dimension name="qc_nitrogen_dioxide_ug_N_per_m3_flags" length="1" />
  <dimension name="qc_nitrogen_monoxide_nmol_per_mol_flags" length="1" />
  <dimension name="qc_nitrogen_monoxide_ug_N_per_m3_flags" length="1" />
  <group name="CFMetadata">
    <attribute name="time_coverage_start" value="2024-09-01T00:00:30Z" />
    <attribute name="time_coverage_end" value="2024-09-30T23:59:30Z" />
    <attribute name="time_coverage_units" value="seconds" />
    <attribute name="time_coverage_resolution" value="60.0" />
    <attribute name="time_coverage_duration" value="P0Y0M29DT23H59M0.000S" />
  </group>
  <group name="NCISOMetadata">
    <attribute name="metadata_creation" value="2026-06-26" />
    <attribute name="nciso_version" value="2.4.8" />
  </group>
  <variable name="time_bnds" shape="time tbnds" type="double">
    <attribute name="long_name" value="time bounds for measurement" />
  </variable>
  <variable name="metadata_time_bnds" shape="metadata_time tbnds" type="double">
    <attribute name="long_name" value="time bounds for ebas metadata intervals" />
  </variable>
  <variable name="v_pressure" shape="d_Location time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="hPa" />
    <attribute name="ancillary_variables" value="qc_pressure meta_pressure" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="pressure" />
    <attribute name="ebas_unit" value="hPa" />
    <attribute name="ebas_matrix" value="instrument" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
  </variable>
  <variable name="qc_pressure" shape="d_Location qc_pressure_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_pressure" shape="d_Location metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_temperature" shape="d_Location time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="K" />
    <attribute name="ancillary_variables" value="qc_temperature meta_temperature" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="temperature" />
    <attribute name="ebas_unit" value="K" />
    <attribute name="ebas_matrix" value="instrument" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
  </variable>
  <variable name="qc_temperature" shape="d_Location qc_temperature_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_temperature" shape="d_Location metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_nitrogen_dioxide_nmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_dioxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="qc_nitrogen_dioxide_nmol_per_mol meta_nitrogen_dioxide_nmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_scale" value="NPL+GPT" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_detection_limit" value="0.029 nmol/mol" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. Detection limit converted from '0.0286 nmol/mol' to '0.0179 ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020. Detection limit converted from '0.0179 ug N/m3' at 273.15 K, 1013.25 hPa to '0.029 nmol/mol', conversion factor 1.60020." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/nitrogendioxideamountfraction" />
    <attribute name="actris_variable_preferred_term" value="nitrogen dioxide amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/scheduled" />
    <attribute name="actris_timeliness_preferred_term" value="scheduled" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/chemiluminescencedetector-photolyticalconverter" />
    <attribute name="actris_instrument_type_preferred_term" value="chemiluminescence detector, photolytical converter" />
    <attribute name="actris_framework_uri" value="" />
    <attribute name="actris_framework_preferred_term" value="" />
    <attribute name="actris_temporal_resolution" value="PT0S" />
    <attribute name="actris_access_restriction" type="long" value="1" />
  </variable>
  <variable name="qc_nitrogen_dioxide_nmol_per_mol" shape="qc_nitrogen_dioxide_nmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_nitrogen_dioxide_nmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_nitrogen_dioxide_ug_N_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_dioxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="qc_nitrogen_dioxide_ug_N_per_m3 meta_nitrogen_dioxide_ug_N_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_dioxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_scale" value="NPL+GPT" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit" value="0.0179 ug N/m3" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. Detection limit converted from '0.0286 nmol/mol' to '0.0179 ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/nitrogendioxidemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="nitrogen dioxide mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_constraints_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/expressedasnitrogen" />
    <attribute name="actris_constraints_preferred_term" value="expressed as nitrogen" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/scheduled" />
    <attribute name="actris_timeliness_preferred_term" value="scheduled" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/chemiluminescencedetector-photolyticalconverter" />
    <attribute name="actris_instrument_type_preferred_term" value="chemiluminescence detector, photolytical converter" />
    <attribute name="actris_framework_uri" value="" />
    <attribute name="actris_framework_preferred_term" value="" />
    <attribute name="actris_temporal_resolution" value="PT0S" />
    <attribute name="actris_access_restriction" type="long" value="1" />
  </variable>
  <variable name="qc_nitrogen_dioxide_ug_N_per_m3" shape="qc_nitrogen_dioxide_ug_N_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_nitrogen_dioxide_ug_N_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_nitrogen_monoxide_nmol_per_mol" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mole_fraction_of_nitrogen_monoxide_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="nmol/mol" />
    <attribute name="ancillary_variables" value="qc_nitrogen_monoxide_nmol_per_mol meta_nitrogen_monoxide_nmol_per_mol" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="nmol/mol" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_scale" value="NPL" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_detection_limit" value="0.02 nmol/mol" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. Detection limit converted from '0.02 nmol/mol' to '0.0125 ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. -- Data converted on export from EBAS from 'ug N/m3' at 273.15 K, 1013.25 hPa to 'nmol/mol', conversion factor 1.60020. Detection limit converted from '0.0125 ug N/m3' at 273.15 K, 1013.25 hPa to '0.02 nmol/mol', conversion factor 1.60020." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/nitricoxideamountfraction" />
    <attribute name="actris_variable_preferred_term" value="nitric oxide amount fraction" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/scheduled" />
    <attribute name="actris_timeliness_preferred_term" value="scheduled" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/chemiluminescencedetector-photolyticalconverter" />
    <attribute name="actris_instrument_type_preferred_term" value="chemiluminescence detector, photolytical converter" />
    <attribute name="actris_framework_uri" value="" />
    <attribute name="actris_framework_preferred_term" value="" />
    <attribute name="actris_temporal_resolution" value="PT0S" />
    <attribute name="actris_access_restriction" type="long" value="1" />
  </variable>
  <variable name="qc_nitrogen_monoxide_nmol_per_mol" shape="qc_nitrogen_monoxide_nmol_per_mol_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_nitrogen_monoxide_nmol_per_mol" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="v_nitrogen_monoxide_ug_N_per_m3" shape="time" type="double">
    <attribute name="_FillValue" type="double" value="NaN" />
    <attribute name="standard_name" value="mass_concentration_of_nitrogen_monoxide_expressed_as_nitrogen_in_air" />
    <attribute name="missing_value" type="double" value="NaN" />
    <attribute name="units" value="ug/m3" />
    <attribute name="ancillary_variables" value="qc_nitrogen_monoxide_ug_N_per_m3 meta_nitrogen_monoxide_ug_N_per_m3" />
    <attribute name="cell_methods" value="time: mean" />
    <attribute name="ebas_data_license" value="" />
    <attribute name="ebas_revision_date" value="2024-12-03T14:13:00.000000Z" />
    <attribute name="ebas_version" value="1" />
    <attribute name="ebas_version_description" value="first revision, manually inspected" />
    <attribute name="ebas_statistics" value="arithmetic mean" />
    <attribute name="ebas_data_level" value="0" />
    <attribute name="ebas_sample_duration" value="1mn" />
    <attribute name="ebas_orig_time_res" value="1mn" />
    <attribute name="ebas_station_code" value="IT0022C" />
    <attribute name="ebas_platform_code" value="IT0022S" />
    <attribute name="ebas_station_name" value="ISAC Bologna II" />
    <attribute name="ebas_station_land_use" value="Residential" />
    <attribute name="ebas_station_setting" value="Suburban" />
    <attribute name="ebas_station_latitude" type="double" value="44.523586" />
    <attribute name="ebas_station_longitude" type="double" value="11.338474" />
    <attribute name="ebas_station_altitude" value="54.0 m" />
    <attribute name="ebas_measurement_height" value="7.0 m" />
    <attribute name="ebas_regime" value="IMG" />
    <attribute name="ebas_component" value="nitrogen_monoxide" />
    <attribute name="ebas_unit" value="ug N/m3" />
    <attribute name="ebas_matrix" value="air" />
    <attribute name="ebas_laboratory_code" value="IT06L" />
    <attribute name="ebas_instrument_type" value="chemiluminescence_photolytic" />
    <attribute name="ebas_instrument_name" value="T200UP_168" />
    <attribute name="ebas_instrument_manufacturer" value="Teledyne" />
    <attribute name="ebas_instrument_model" value="T200UP" />
    <attribute name="ebas_instrument_serial_number" value="168" />
    <attribute name="ebas_method_ref" value="IT06L_chem_photoly_TeledyneT200UP_IMP2024" />
    <attribute name="ebas_standard_method" value="SOP=ACTRIS_NOxy_2014" />
    <attribute name="ebas_calibration_scale" value="NPL" />
    <attribute name="ebas_calibration_standard_id" value="Status calibration standard: 1, Manufacturer: NPL, Batch: D109110" />
    <attribute name="ebas_inlet_type" value="Hat or hood" />
    <attribute name="ebas_inlet_description" value="The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe" />
    <attribute name="ebas_inlet_tube_material" value="Teflon" />
    <attribute name="ebas_ozone_correction" value="Not corrected for reaction with O3 in the inlet" />
    <attribute name="ebas_water_vapor_correction" value="Not corrected for water vapor quenching in CLD" />
    <attribute name="ebas_humidity_temperaure_control" value="None" />
    <attribute name="ebas_volume_std_temperature" value="273.15 K" />
    <attribute name="ebas_volume_std_pressure" value="1013.25 hPa" />
    <attribute name="ebas_detection_limit" value="0.0125 ug N/m3" />
    <attribute name="ebas_detection_limit_expl" value="Determined by zero noise" />
    <attribute name="ebas_measurement_uncertainty_expl" value="Includes statistical uncertainty of individual sample and calibration uncertainty" />
    <attribute name="ebas_zero_negative_values_code" value="Zero/negative possible" />
    <attribute name="ebas_zero_negative_values" value="Zero and neg. values may appear due to statistical variations at very low concentrations" />
    <attribute name="ebas_organization" value="IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy" />
    <attribute name="ebas_framework_acronym" value="CAMPAIGN" />
    <attribute name="ebas_framework_name" value="" />
    <attribute name="ebas_framework_description" value="" />
    <attribute name="ebas_framework_contact_name" value="Wenche Aas" />
    <attribute name="ebas_framework_contact_email" value="waa@nilu.no" />
    <attribute name="ebas_originator" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;, &quot;Cristofanelli, Paolo, p.cristofanelli@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, , I-4019, Bologna, Italy&quot;, &quot;Busetto, Maurizio, m.busetto@isac.cnr.it, National Research Council of Italy, CNR, Institute for Atmospheric and Climate Science, Via Gobetti 101, I-4019, , Bologna, Italy&quot;" />
    <attribute name="ebas_submitter" value="&quot;Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy&quot;" />
    <attribute name="ebas_acknowledgement" value="Data used in this &lt;study/report/figure/etc.&gt; were accessed from EBAS (https://ebas.nilu.no) hosted by NILU. Specifically, the use included data affiliated with the framework: CAMPAIGN. Request acknowledgement details from data originator" />
    <attribute name="ebas_comment" value="Data converted on import into EBAS from 'nmol/mol' to 'ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923. Detection limit converted from '0.02 nmol/mol' to '0.0125 ug N/m3' at 273.15 K, 1013.25 hPa, conversion factor 0.624923." />
    <attribute name="actris_variable_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/nitricoxidemassconcentration" />
    <attribute name="actris_variable_preferred_term" value="nitric oxide mass concentration" />
    <attribute name="actris_matrix_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/gasphase" />
    <attribute name="actris_matrix_preferred_term" value="gas phase" />
    <attribute name="actris_constraints_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/expressedasnitrogen" />
    <attribute name="actris_constraints_preferred_term" value="expressed as nitrogen" />
    <attribute name="actris_timeliness_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/scheduled" />
    <attribute name="actris_timeliness_preferred_term" value="scheduled" />
    <attribute name="actris_instrument_type_uri" value="https://vocabulary.actris.nilu.no/actris_vocab/chemiluminescencedetector-photolyticalconverter" />
    <attribute name="actris_instrument_type_preferred_term" value="chemiluminescence detector, photolytical converter" />
    <attribute name="actris_framework_uri" value="" />
    <attribute name="actris_framework_preferred_term" value="" />
    <attribute name="actris_temporal_resolution" value="PT0S" />
    <attribute name="actris_access_restriction" type="long" value="1" />
  </variable>
  <variable name="qc_nitrogen_monoxide_ug_N_per_m3" shape="qc_nitrogen_monoxide_ug_N_per_m3_flags time" type="int">
    <attribute name="_FillValue" type="int" value="0" />
    <attribute name="standard_name" value="status_flag" />
    <attribute name="missing_value" type="int" value="0" />
    <attribute name="units" value="1" />
  </variable>
  <variable name="meta_nitrogen_monoxide_ug_N_per_m3" shape="metadata_time" type="String">
    <attribute name="long_name" value="ebas metadata for different time intervals; json encoded" />
  </variable>
  <variable name="time" shape="time" type="double">
    <attribute name="long_name" value="time of measurement" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01T00:00:00Z" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="standard" />
    <attribute name="bounds" value="time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>
  <variable name="metadata_time" shape="metadata_time" type="double">
    <attribute name="long_name" value="time of ebas metadata intervals" />
    <attribute name="standard_name" value="time" />
    <attribute name="units" value="days since 1900-01-01T00:00:00Z" />
    <attribute name="axis" value="T" />
    <attribute name="calendar" value="standard" />
    <attribute name="bounds" value="metadata_time_bnds" />
    <attribute name="_CoordinateAxisType" value="Time" />
  </variable>
  <variable name="d_Location" shape="d_Location" type="String" />